Single stream Flow & Energy Computer for water and saturated / superheated steam
A
Options
ZL - Data logging
Backlight
ZB - Adjustable backlight
Hazardous Area
XX - Safe area only
Temperature input signal
TZ - Pt100 / Pt500 or analog 4 - 20 mA temperature input
Additional inputs
IR - 2 x status inputs
IA - Analog 4 - 20 mA input for pressure signal
Flow Equations
ES - Flow equations for water and steam (saturated / superheated)
3 x analog (4-20 mA) input, selectable as Active or Passive. Suitable for dP elements incl. stacked sensors (orifices, nozzles, venturies, V-cones, wedge meters, Pitot tubes, etc.) and flowmeters with a linear analog output signal.
Update time: 10 times per second.
Linearization:The signal can be linearized over 11 points.
Isolation:Inputs are isolated from communication ports, the power supply and passive analog outputs.