F130
Batch controller, two control outputs: 2-stage control or pulse output
Step 1 of 11
Select Input signal
Restart
P
Info
Pulse input: Namur, Coil, reed, NPN (PNP) open collector/drain
Option P
Option details P
Coil / sine wave (minimum 20mVpp or 80mVpp - sensitivity selectable), NPN/PNP (open collector/drain), reedswitch, Namur, active pulse signals 8 - 12 and 24V DC.
Frequency
Minimum 0Hz - maximum 7kHz for total and flow rate. Maximum frequency depends on signal type and
internal low-pass filter. E.g. reed switch with low-pass filter: max. frequency 120Hz.
K-Factor
0.000010 - 9,999,999 with variable decimal position.
Low-pass filter
Available for all pulse signals.
Option
ZF coil sensitivity 10mVpp. ZG (if available) coil sensitivity 5mVpp.
Restart
Ordering Code: F130
Restart
Are you sure you want to change to this option and go back in the configuration?
Confirm
Cancel